| Light transmission | The share of visible light that reaches the interior. Clear solid sheet passes close to 90 percent; multiwall grades range roughly from 40 to 80 percent by wall count and tint. | Higher is not automatically better. Diffusing grades transmit less on paper but light the floor more usefully, without glare patches over workstations. |
|---|
| U-value | How fast heat crosses the glazing. Multiwall sheet traps air in its channels: even twinwall beats single glazing, and thick five- and seven-wall sheets approach double-glazed performance. | Compare center-of-glazing versus whole-unit numbers. A superb sheet in an uninsulated aluminum frame loses much of its advantage at the perimeter. |
|---|
| Solar heat gain (SHGC) | How much of the sun's heat comes in with the light. Tints, opal diffusion and IR-blocking grades pull the number down for cooling climates. | In heating climates some gain is welcome. Match SHGC to the climate zone and the energy code, not to a generic 'lower is better' rule. |
|---|
| Multiwall vs solid | Solid sheet is glass-like and strongest against point impact; multiwall is lighter per area, far better insulating, and inherently diffusing in opal grades. | The wall count and thickness must match the span and load tables. A thicker sheet is not stronger if the ribs run the wrong way for the span. |
|---|
| Impact & hail rating | Documented resistance to hail and debris, from material-level impact values to unit-level severe-hail approvals used by insurers. | Ask for the tested assembly, not the resin brochure. A tough sheet in a brittle frame or with weak fastening still fails at the connection. |
|---|
| Fire classification | Light-transmitting plastics are classified by burning behavior under the building code, which drives allowable areas, separations and where units may be installed. | Confirm the classification of the actual sheet being supplied. Area limits as a fraction of the roof differ by class, and the code official will check. |
|---|
| Condensation control | How the unit manages the moisture a warm humid interior pushes at cold glazing: thermal breaks, condensation gutters, vented and taped flute ends. | Over pools, washdown areas and greenhouses this spec matters more than U-value. Ask specifically how the unit drains what condenses. |
|---|
| Fall protection provisions | Whether the unit ships with, or accepts, a screen or security bar system, and whether the assembly is tested against a person falling onto it. | OSHA treats every skylight as a hole in the roof. Protection is a requirement of working near one, whatever the glazing material. |
|---|